SR6602I-CMW910-R9119P17

Release time:2024-10-08
HomeSupportRoutersSR6602-I[IE] SeriesSoftware DownloadSR6602-I[IE] Series

H3C SR6602I-CMW910-R9119P17 Release Notes

 

Contents

Version information· 1

Version number· 1

Version history· 1

Hardware and software compatibility matrix· 1

Upgrading restrictions and guidelines· 3

Hardware feature updates· 3

CMW910-R9119P17· 3

CMW910-R9119P16· 3

CMW910-R9119P15· 3

CMW910-R9119P12· 3

CMW910-R9112P06· 3

Software feature and command updates· 4

MIB updates· 4

Operation changes· 4

Restrictions and cautions· 4

Open problems and workarounds· 4

List of resolved problems· 5

Resolved problems in CMW910-R9119P17· 5

Resolved problems in CMW910-R9119P16· 7

Resolved problems in CMW910-R9119P15· 8

Resolved problems in CMW910-R9119P12· 10

Related documentation· 11

Documentation set 11

Obtaining documentation· 12

Technical support 12

Appendix A Feature list 13

Hardware features· 13

Software features· 15

Appendix B Upgrading software· 18

Software types· 18

Upgrade methods· 18

Preparing for the upgrade· 19

Upgrading from the CLI 19

Saving the running configuration and verifying the storage space· 20

Downloading the image file to the router· 20

Specifying the startup image file· 21

Rebooting and completing the upgrade· 22

Upgrading from the BootWare menu· 23

Accessing the BootWare menu· 23

Using TFTP/FTP to upgrade software through an Ethernet port 25

Using XMODEM to upgrade software through the console port 28

Managing files from the BootWare menu· 32

Displaying all files· 33

Changing the type of a system software image· 34

Deleting files· 34

Handling software upgrade failures· 35

Appendix C Handling console login password loss· 35

Disabling password recovery capability· 35

Handling console login password loss· 36

Examining the password recovery capability setting· 37

Using the Skip Current System Configuration option· 38

Using the Skip Authentication for Console Login option· 39

Using the Restore to Factory Default Configuration option· 40



This document describes the features, restrictions and guidelines, open problems, and workarounds for version R9119P17. Before you use this version in a live network, back up the configuration and test the version to avoid software upgrade affecting your live network. Use this document in conjunction with H3C SR6602I-CMW910-R9119P17 Release Notes (Software Feature Changes) and the documents listed in "Related documentation."

Version information

Version number

H3C Comware Software, Version 9.1.041, Release 9119P17

Note: You can see the version number with the command display version in any view. Please see Note.

Version history

Table 1 Version history

Version number

Last version

Release date

Release type

Remarks

CMW710-R9119P17

CMW710-R9119P16

2023-08-22

Release version

·         Fixes bugs

CMW710-R9119P16

CMW710-R9119P15

2023-05-23

Release version

·         Fixes bugs

CMW710-R9119P15

CMW710-R9119P12

2023-02-23

Release version

·         Fixes bugs

CMW710-R9119P12

CMW710-R9112P09

 

2022-06-28

Release version

·         New feature:

1. interface channelization

2. IFIT

3.SRv6

·      Fixes bugs

CMW710-R9112P09

CMW710-R9112P06

2022-04-08

Release version

·      Fixes bugs

CMW710-R9112P06

First release

2021-08-10

Release version

·      First release

Hardware and software compatibility matrix

 

CAUTION

CAUTION:

To avoid an upgrade failure, use Table 2 to verify the hardware and software compatibility before performing an upgrade.

 

Table 2 Hardware and software compatibility matrix

Item

Specifications

Product family

SR6602-I/SR6602-IE

Boot ROM version

SR6602I: 118 or higher

 (Note: Perform the command display version command in any view to view the version information. Please see Note)

Host software

Hardware

software

MD5 Check Sum

SR6602-I_SR6602-IE

SR6602I-CMW910-R9119P17.ipe    

491cb4868a83ab50d3b6f53b6f9b2729

MC version

iMC FCAPS(E0711)

iMC AOM(E0706P01)

iMC ACLM (E0706P12)

iMC BIMS 7.3 (E0509)

iMC DM 7.3(E0706P12)

iMC EAD 7.3 (E0627)

iMC EIA 7.3 (E0627)

iMC EIA 7.3 (E0627)

iMC iCC 7.3(E0706P12)

iMC IVM 7.3 (E0508)

iMC MVM 7.3 (E0511)

iMC NTA 7.3 (E0507)

iMC PLAT 7.3 (E0706P12)

iMC QoSM 7.3 (E0506P01)

iMC SHM 7.3 (E0511)

UCenter E0709

iMC VLAN 7.3 (E0706P12)

iMC VXLAN 7.3 (E0706P12)

iNode version

iNode PC 7.3 (E0585)

 

Please see the example below generated by the display version command:

<Sysname> display version     

H3C Comware Software, Version 9.0.001, Release 9119P17        ------- Note                 

Copyright (c) 2004-2022 New H3C Technologies Co., Ltd. All rights reserved.    

H3C SR6602 uptime is 1 week, 1 day, 3 hours, 7 minutes                         

Last reboot reason : Power on                                                  

Boot image: sda0:/sr6602i-cmw910-boot-r9119p17.bin                             

Boot image version: 9.0.001, Release 9119P17                                   

  Compiled Apr 08 2022 11:00:00                                                

System image: sda0:/sr6602i-cmw910-system-r9119p17.bin                         

System image version: 9.0.001, Release 9119P17                                 

  Compiled Apr 08 2022 11:00:00                                                

Feature image(s) list:                                                          

  sda0:/sr6602i-cmw910-virtualization-r9119p17.bin, version: 9.0.001           

    Compiled Apr 08 2022 11:00:00                                              

                                                                                

Slot 0: RT-SR6602-I uptime is 1 week, 1 day, 3 hours, 7 minutes                

 Last reboot reason : Power on                                                 

 CPU ID: 1                                                                      

 8G bytes DDR4 SDRAM Memory                                                    

 32M bytes Flash Memory                                                        

 PCB              Version: A                                                    

 FPGA             Version: 2.16                                                

 Basic      CPLD  Version: 1.0                                                 

 Extend     CPLD  Version: 1.0                                                 

 Basic   BootWare Version: 1.18        ------- Note                                          

 Extend  BootWare Version: 1.18                                                

 [FIXED PORTS] CON              (Hardware)Ver.A,   (Driver)1.0,   (CPLD)1.0    

 [FIXED PORTS] MGE              (Hardware)Ver.A,   (Driver)1.0,   (CPLD)1.0    

 [FIXED PORTS] 6XGE             (Hardware)Ver.A,   (Driver)1.0,   (CPLD)1.0    

 [FIXED PORTS] 14XGSW           (Hardware)Ver.A,   (Driver)1.0,   (CPLD)1.0    

 [FIXED PORTS] 12GSW            (Hardware)Ver.A,   (Driver)1.0,   (CPLD)1.0

Upgrading restrictions and guidelines

None

Hardware feature updates

CMW910-R9119P17

None

CMW910-R9119P16

None

CMW910-R9119P15

None

CMW910-R9119P12

None

CMW910-R9112P06

None

Software feature and command updates

For more information about the software feature and command update history, see H3C SR6602I-CMW910-R9119P17 Release Notes (Software Feature Changes).

MIB updates

None.

Operation changes

None

Restrictions and cautions

R9119P14 and earlier versions do not support Web configuration. Do not configure features through Web. To use Web UI, upgrade the software version to R9135P04 or later as a best practice.

Open problems and workarounds

202210131303

·          Symptom: GE/XGE interfaces on an FIP30 module of an SR6602I/IE router cannot achieve line-rate forwarding in a small-packet traffic scenario.

·          Condition: This symptom occurs if GE/XGE interfaces on an FIP30 module of an SR6602I/IE router forwards traffic of small packets.

·          Workaround: This problem will be fixed in later versions.

202304251195

·          Symptom: Packets can be exchanged between interfaces in the same security zone before the security-zone intra-zone default permit command is executed in system view. Normally, the system should drop such packets.

·          Condition: This symptom might occur if you add different interfaces to the same security zone but do not execute the security-zone intra-zone default permit command in system view.

·          Workaround: This problem will be fixed in later versions.

202304270197

·          Symptom: If you apply a security policy that uses an IPS policy and then inject traffic that matches the IPS characteristics, the system fails to take the action defined in the IPS policy on some traffic.

·          Condition: This symptom might occur if you apply a security policy that uses an IPS policy.

·          Workaround: Apply security policies and IPS policies separately.

202308091585

·          Symptom: When a USB drive is divided into multiple partitions before being re-partitioned into a single partition, the system prompts a failed operation, but the operation actually has succeeded.

·          Condition: This symptom occurs if a USB drive is divided into multiple partitions before being re-partitioned into a single partition. It is currently unclear whether the issue is caused by the size or model of the USB drive.

·          Workaround: This problem will be fixed in later versions.

202308251254

·          Symptom: When a Layer 2 aggregate interface is created, its MAC address is all-zeros.

·          Condition: This symptom occurs if you create a Layer 2 aggregate interface.

·          Workaround: Do not use the MAC address of a Layer 2 aggregate interface on the network. This problem will be fixed in later versions.

202308071903

·          Symptom: The controller manages to access the device using the correct username and password via SSH, but because of incorrect authorization attributes, the controller experiences an abnormal logout. This results in residual line resources in the database management module (DBM), which prevents further user logins.

·          Condition: This symptom occurs when the controller gains access to the device using the correct credentials via SSH, but the user's authorization attributes are not configured accurately.

·          Workaround: This problem will be fixed in later versions.

202308071832

·          Symptom: For the controller to log in to the device through SSH, you need to execute the free command to release the residual user line information in DBM.

·          Condition: This symptom occurs if the controller attempts to log in to the device through SSH.

·          Workaround: This problem will be fixed in later versions.

List of resolved problems

Resolved problems in CMW910-R9119P17

202307030141

·          Symptom: The NetStream output packets are sent on the control core 0, which consumes a significant amount of CPU resources. Heavy traffic causes packet transmission failures for protocols like BGP due to CPU resource issues, leading to service flapping.

·          Condition: This symptom occurs if protocol flapping occurs during forwarding of a large number of packets.

202308070219

·          Symptom: If repeated attempts are made to log in to the device via Telnet with incorrect passwords, or if the device is attacked by similar operations, some memory files in the device might not be properly deleted. Prolonged operations or attacks can lead to insufficient memory in the device, causing a device reboot.

·          Condition: This symptom occurs if repeated attempts are made to log in to the device via Telnet with incorrect passwords, or if the device is attacked by similar operations.

202305310821

·          Symptom: Send a massive amount of traffic to the device to generate 10 million fast forwarding entries, which causes the memory usage to approach the minor memory threshold. After the fast forwarding entries age out, 30% of the memory is not released and is inaccessible.

·          Condition: This symptom occurs if the device receives a massive amount of traffic and generates a large number of fast forwarding entries, which occupy a large amount of memory.

202305221038

·          Symptom: On the Network > Port Management page of the Web interface, configure an interface to operate in half duplex mode and then configure it to operate in full duplex mode, and configure the interface to operate at 1 Gbps. In this case, the system prompts that the configuration fails to be deployed.

·          Condition: This symptom occurs if the following operations are performed on the Network > Port Management page of the Web interface:

a.           Configure an interface to operate in half duplex mode and then configure it to operate in full duplex mode.

b.          Configure the interface to operate at 1 Gbps.

202305191517

·          Symptom: The Output(Total) field value, which displays the number of outgoing packets on an interface, is displayed abnormally. The PPS value in the Last 30 seconds outputs field for an interface is abnormal. As a result, the interface bandwidth is exceeded and the bandwidth usage reaches 100%, and alarms are generated.

·          Condition: This symptom might occur if interface data reading actions are performed concurrently for many times, which will cause the driver to collect statistics incorrectly with a low probability.

202304230323

·          Symptom: On the Web interface, the per-IP TCP connection upper limit does not take effect.

·          Condition: This symptom occurs if you perform the following operations:

a.           On the Add Connection Limit Rule page, configure the per-IP connection upper limit and per-IP UDP connection upper limit, and click Apply.

b.          Click the edit icon for the rule, configure the per-IP TCP connection upper limit on the Modify Connection Limit Rule page, and click Apply.

c.           Click the edit icon for the rule, delete the per-IP UDP connection upper limit on the Modify Connection Limit Rule page, and click Apply.

202304131322

·          Symptom: For the SR6602I/IE device, if you configure Track to monitor collaboration between static route and NQA, packet loss might occur in the NQA ICMP-echo operation.

·          Condition: This symptom might occur with a certain probability if you configure Track to monitor collaboration between static route and NQA for the SR6602I/IE device.

Resolved problems in CMW910-R9119P16

202302211003

·          Symptom: A device cannot ping a destination because the actual length of the ICMP echo requests is not the same as the length specified in the ping –s -r command.

·          Condition: This symptom occurs if the echo request length specified in the ping –s -r command is 200 with a fluctuation around 20.

202302210378

·          Symptom: On an SR6602-I or SR6602-IE router installed with an RT-MIC-X-CLP2 (CPOS) module, operation fails when you change the framing format of a controller interface after the controller interface is divided into multiple serial interfaces. As a result, all of the serial interfaces go down. You can bring up the serial interfaces only after rebooting the module.

·          Condition: This symptom occurs if the following conditions exist:

¡  The SR6602-I or SR6602-IE router is installed with an RT-MIC-X-CLP2 (CPOS) module.

¡  The framing format of a controller interface is changed after the controller interface is divided into multiple serial interfaces.

202302201459

·          Symptom: On the Network > LAN Settings page of the Web interface for the SR6602I/IE device, no prompt message appears when you switch an interface from a GE interface to a LAN interface.

·          Condition: This symptom might occur if you switch an interface from a GE interface to a LAN interface on the Network > LAN Settings page of the Web interface for the SR6602I/IE device.

202302040295

·          Symptom: On the System Information page of the Web interface for the SR6602I/IE device, the interface rate statistics graph does not display traffic statistics on interfaces.

·          Condition: This symptom might occur if you view traffic statistics on an interface on the corresponding rate statistics graph on the System Information page of the Web interface for the SR6602I/IE device.

202212130756

·          Symptom: When you create an application group, and then upgrade the APR signature library, you cannot edit the application group after the upgrade. However, the system still displays that the application group is user-defined.

·          Condition: This symptom might occur if you create an application group, upgrade the APR signature library, and then edit the application group after the upgrade.

202211030757

·          Symptom: If you enable DHCP snooping both globally and for VLANs in different configuration orders, the effective rules issued to the driver are different. As a result, DHCP snooping malfunction occurs.

·          Condition: This symptom might occur if DHCP snooping is enabled both globally and for VLANs.

202304030297

·          Symptom: When BGP uses a peer address range (non-unicast addresses) to establish peer relationships, it cannot correctly establish peer relationships with some of the addresses in the address range.

·          Condition: This symptom occurs if BGP uses a peer address range (non-unicast addresses) to establish peer relationships.

202304240520

·          Symptom: The overall forwarding efficiency degrades after the device receives a large number of packets to unknown destinations.

·          Condition: This symptom might occur after the device receives a large number of packets to unknown destinations.

Resolved problems in CMW910-R9119P15

202212280307

·          Symptom: PPPoE dialup is performed on a WAN interface. After an L2TP user comes online and pings the VT interface address, the LNS crashes and becomes unavailable.

·          Condition: This symptom occurs if the following operations are performed:

a.           PPPoE dialup is performed on a WAN interface.

b.          After an L2TP user comes online, the user pings the VT interface address.

202209030481

·          Symptom: The device prints Deadloop detected on cpu 0 core 1 repeatedly and fails to forward NAT traffic of the NAT session last established.

·          Condition: This symptom occurs if have configured a large number of NAT server mappings that meet the following conditions:

¡  Each NAT server mapping has the same public IP address and different public port numbers.

202206200185

·          Symptom: Fragmented SCTP data packets cannot be forwarded because the first fragmented SCTP data packet is dropped by ASPF.

·          Condition: This symptom occurs if fragmented SCTP data packets cannot be forwarded.

202206230754

·          Symptom: After a USB drive is removed, .the device mistakenly prompts the message The device does not exist when you save a .cfg file to the previous path for the removed USB drive.

·          Condition: This symptom might occur when you save a .cfg file to the previous path for a removed USB drive.

202206021368

·          Symptom: After an amount of traffic triggers MAC authentication, some MAC addresses are mistakenly added to the MAC address table as dynamically learned MAC addresses.

·          Condition: This symptom might occur when you view the MAC address table after an amount of traffic triggers MAC authentication.

202207040549

·          Symptom: The device is installed with a SIC-5G interface module and two SIM cards are present. When the primary SIM card has no signal or the dialup fails, the device fails to switch to the secondary SIM card.

·          Condition: This symptom might occur when two SIM cards are present and the primary SIM card has no signal or the dialup fails.

202206291452

·          Symptom: When the IPv6 single-stack automatic dialup mode is configured on a 5G interface, the 5G interface cannot automatically dial up to obtain an IPv6 address after the modem is rebooted. You must delete and then execute the ipv6 address cellular-alloc command again.

·          Condition: This symptom occurs if the IPv6 single-stack automatic dialup mode is configured on a 5G interface and the modem is rebooted.

202206291094

·          Symptom: IMC cannot sample flows based on the BGP AS number by using the NetStream component.

·          Condition: This symptom occurs if IMC samples flows based on the BGP AS number by using the NetStream component.

202206231138

·          Symptom: If the display interface brief command is executed when a large number of subinterfaces are configured, the command output is displayed slowly.

·          Condition: This symptom occurs if the display interface brief command is executed when a large number of subinterfaces are configured and you view the command output.

202206171668

·          Symptom: Delete the segment-routing ipv6 configuration, and then deploy the locator configuration. Additional anycast enable configuration is generated.

·          Condition: This symptom occurs when you delete the segment-routing ipv6 configuration, and then deploy the locator configuration.

202205231309

·          Symptom: When the device run OSPFv3 in some scenarios, the OSPFv3 process might failed to be deployed. After you use the follow command to display stack information for the process, the process will recover.

·          Condition: This symptom occurs if the following conditions exist:

a.           You use the vpn-instance command to create a VPN instance, and no OSPFv3 instances run on the VPN instance.

b.          You use the ip binding vpn-instance command associate an interface with the VPN instance.

You configure an IPv6 address for the interface by using the ipv6 address command.

You execute a minimum of one OSPFv3 pre-configuration command on the interface, but do not enable OSPFv3 on the interface.

c.           You perform one of the following tasks:

-      You use the undo ip binding vpn-instance command to unbind the VPN instance from the interfaces on the device.

When the device has only one interface associated with the VPN instance and you continue to unbind the interface from the VPN instance, this symptom might occur.

-      You delete the VPN instance directly.

202204131807

·          Symptom: The device has two ECMP routes to reach an IP address. The output interface of one route is a main interface and the output interface of the other route is a subinterface of the main interface. When you ping the IP address, the device sends the ICMP echo requests through the subinterface, but the source IP address of the requests is the IP address of the main interface.

·          Condition: This symptom occurs if the following conditions exist:

¡  The device has two ECMP routes to reach the pinged IP address.

¡  The output interface of one route is a main interface and the output interface of the other route is a subinterface of the main interface.

202206110680

·          Symptom: The ping communication over an IPsec tunnel fails on the SR6602-I/IE device.

·          Condition: This symptom occurs when the interface applied with an IPsec policy has a MTU greater than 2000, the IPsec uses the built-in hardware encryption card and GM encryption card, and the packet length is between 1931 to 1946 bytes.

Resolved problems in CMW910-R9119P12

202205190948

·          Symptom: In an EVPN L3VPN over SRv6 network, the device takes about half an hour before it can advertise EVPN private network routes to peers after L2VPN is enabled and then disabled on it.

·          Condition: This symptom occurs if the following operations are performed on the device in an EVPN L3VPN over SRv6 network:

a.           Enable L2VPN and then disable it.

b.          Re-advertise EVPN private network routes.

202205171465

·          Symptom: The console is stuck after the docker start -i comware command is executed in system view.

·          Condition: This symptom occurs if you execute the docker start -i comware command in system view.

202205131400

·          Symptom: The console is stuck after the packet-capture interface xx port x command is executed in user view.

·          Condition: This symptom occurs if you execute the packet-capture interface xx port x command in user view.

202205230921

·          Symptom: Enable webcache (with listening port 179), configure BGP, and then delete the webcache configuration. The BGP neighbor relationship cannot be established. This issue cannot be resolved by executing the reset bgp command. You must reconfigure BGP to resolve this issue.

·          Condition: This symptom occurs when you enable webcache (with listening port 179), configure BGP, and then delete the webcache configuration.

202205231503

·          Symptom: After you issue PBR settings on the Web interface, the PBR page gets stuck, and the system cannot display the issued PBR settings. You can restore the page by deleting all PBR settings at the back end.

·          Condition: This symptom occurs when you issue PBR settings on the Web interface.

202205191658

·          Symptom: When the device is low on memory, the OS kills the BGP process and the COMSH process. After the device memory restores to normal condition, the device does not restart those processes.

·          Condition: The device is low on memory.

202205240918

·          Symptom: In a multihomed EVPN VPWS site, a PE encapsulates incorrect private labels into packets, and traffic forwarding fails as a result.

·          Condition: This symptom occurs if IS-IS is reset and a PE sends traffic to remote PEs at a dualhomed site.

202204280573

·          Symptom: The nat server command does not take effect.

·          Condition: This symptom occurs if you specify the private port as dns when executing the nat server command.

202204140101

·          Symptom: In an EVPN VPWS over SRv6 network, the entries in user mode and kernel mode are inconsistent when multiple SRv6 TE ECMP tunnels exist.

·          Condition: This symptom occurs in an EVPN VPWS over SRv6 network if multiple SRv6 TE ECMP tunnels exist..

Related documentation

Documentation set

·          H3C SR6602-I[IE] AI Series ICT Converged Gateways Installation Quick Start

·          H3C SR6602-I[IE] AI-Powered ICT Converged Gateways Interface Card Guide

·          H3C SR6602-I[IE] AI Series ICT Converged Gateways Installation Guide

·          H3C SR6602-I[IE] AI Series ICT Converged Gateways Hardware Information and Specifications

·          H3C SR6602-I[IE] AI-Powered ICT Converged Gateways Command References(V9)

·          H3C SR6602-I[IE] AI-Powered ICT Converged Gateways VM Deployment Guide

·          H3C SR6602-I[IE] AI-Powered ICT Converged Gateways Configuration Guides(V9)

·          H3C SR6602-I[IE] AI-Powered ICT Converged Gateways System Log Messages Reference

Obtaining documentation

Take the following steps to get related documents from the H3C website at www.h3c.com.

1.          Go to  https://www.h3c.com/

2.         Choose the desired product category and model.

Technical support

To obtain technical assistance, contact H3C by using one of the following methods:

·          Email:

[email protected] (countries and regions except Hong Kong, China)

[email protected] (Hong Kong, China)

·          Technical support hotline number. To obtain your local technical support hotline number, go to the H3C Service Hotlines website: https://www.h3c.com/en/Support/Online_Help/Service_Hotlines/

To access documentation, go to the H3C website at http://www.h3c.com/en/.

 


Appendix A Feature list

Hardware features

Table 3 SR6602-I/SR6602-IE specifications

Item

SR6602-I

SR6602-IE

CPU

8 cores, 2.5 GHz

12 cores, 2.3 GHz

Built-in WAN port

6 × 10-GE SFP+ ports

6 × 10-GE SFP+ ports

Built-in LAN port (supports LAN/WAN switching)

14 × 10-GE SFP+ ports and 12 × GE RJ-45 ports

14 × 10-GE SFP+ ports and 12 × GE RJ-45 ports

FIP slot

1 × FIP slot (supports the FIP-30)

1 × FIP slot (supports the FIP-30)

PCIe slot

1

1

Memory slot

4CH DDR4 RDIMM slots

4CH DDR4 RDIMM slots

Memory size (default/maximum)

8 G/128 G

32 G/128 G

Built-in storage

4 GB

64 GB

External SATA drive slot

2 × 2.5-inch slots

2 × 2.5-inch slots

Internal M.2 SSD slot

1

1

USB 3.0 port

1

1

Console port

1

1

Open-source application management platforms supported

KVM, Docker

KVM, Docker

Maximum power consumption (aggregation mode/converged mode)

224 W/558 W

239 W/567 W

Power supply redundancy

Supported

Supported

Removable fan trays

2

2

Power input voltage

AC: 100 V to 240 V

DC: –48 V to –60 V

HVDC: 240 V to 380 V

AC: 100 V to 240 V

DC: –48 V to –60 V

HVDC: 240 V to 380 V

Height

2 RU

2 RU

Dimensions (H × W × D)

88 × 440 × 480 mm (3.46 × 17.32 × 18.90 in)

88 × 440 × 480 mm (3.46 × 17.32 × 18.90 in)

Operating temperature

Without drives or GPUs: 0°C to 45°C (32°F to 113°F)

With drives or GPUs: 0°C to 40°C (32°F to 104°F)

Ambient humidity

5 % RH to 95% RH, noncondensing

Storage temperature

40°C to +70°C (–40°F to +158°F)

EMC compliance

FCC Part 15 (CFR 47) CLASS A

ICES-003 CLASS A

VCCI-3 CLASS A

VCCI-4 CLASS A

CISPR 22 CLASS A

EN 55022 CLASS A

AS/NZS CISPR22 CLASS A

CISPR 24

EN 55024

EN 61000-3-2

EN 61000-3-3

EN 61000-6-1

ETSI EN 300 386

EN 301 489-1

EN 301 489-17

Safety compliance

UL 60950-1

CAN/CSA C22.2 No 60950-1

IEC 60950-1

EN 60950-1/A11

AS/NZS 60950

EN 60825-1

EN 60825-2

FDA 21 CFR Subchapter J

GB 4943

 

Table 4 Interface modules available for the SR6602-I/SR6602-IE router

For compatibility between the router and interface modules, see the interface module guide for the router.

Item

Description

MIC-X

Ethernet interface modules:

·         MIC-X-XP4: 4-port 10GBASE-R Ethernet optical interface card(SFP+,LC)(MIC-X)

·         MIC-X-XP2: 2-port 10GBASE-R Ethernet optical interface card(SFP+,LC)(MIC-X)

WAN interface modules:

·         MIC-X-CLP2: 2-port OC-3/STM-1 channelized POS optical interface card(SFP,LC)(MIC-X)

·         MIC-X-CLP4: 4-port OC-3/STM-1 channelized POS optical interface card(SFP,LC)(MIC-X)

·         MIC-X-SP4: 4-port OC-3c/STM-1c POS or 1-port OC-12c/STM-4c POS optical interface card(SFP,LC)(MIC-X)

·         MIC-X-SP8: 8-port OC-3c/STM-1c POS optical interface card(SFP,LC)(MIC-X)

·         MIC-X-ET16: 16-port E1/T1 copper interface card(HM96 male connector)(MIC-X)

·         MIC-X-CNDE-SJK: SCA SM encryption module(SM1/2/3/4 supported)(MIC-X)

PCI-E

GPU module:

UN-GPU-P40-X: P40 GPU accelerator module

RAID controller:

UN-HBA-H460-B1: 12Gb 2 ports SAS HBA card(8 SAS ports)

Software features

Table 5 SR6602-I/SR6602-IE features

Item

Specification

Layer 2 protocol

Ethernet, Ethernet II, VLAN, 802.1p, 802.1Q, 802.1X, STP (802.1D), RSTP (802.1w), MSTP (802.1s), PPP, PPPoE client, PPPoE server

IP services

Unicast/multicast, TCP, UDP, IP option, IP unnumbered, policy-based routing, NetStream

ECMP

UCMP

IP application

Ping, Tracert, ICMP, DHCP server, DHCP relay, DHCP client, DNS client, DNS proxy, DDNS, NTP, SNTP

IPv4 routing

Static routing

Dynamic routing: RIPv1/v2, OSPFv2, BGP, IS-IS

Routing policy

Multicast routing: IGMPv1/v2/v3, PIM-DM, PIM-SM, MBGP, MSDP

IPv6

IPv6 ND, IPv6 PMTU, IPv6 FIB, IPv6 ACL, NAT-PT, IPv6 tunnel, 6PE

IPv6 tunneling technologies: manual tunneling, automatic tunneling, GRE tunnel, 6to4, ISATAP

Static routing

Dynamic routing: RIPng, OSPFv3, IS-ISv6, BGP4+

IPv6 multicast: MLDv1/v2, PIM-DM, PIM-SM

QoS

LR

Committed access rate (CAR)

FIFO, WFQ, CBQ

Generic Traffic Shaping (GTS)

Traffic classification

Support network slicing on routing subinterfaces and aggregate subinterfaces

Security

Portal, 802.1X, IP source guard

Local authentication, RBAC, RADIUS, TACACS

ACL, filter, connection limit

IKE/IKEv2, IPsec

ADVPN

L2TP, NATPKI, RSA, SSHv1.5/2.0, URPF, and GRE

ARP attack prevention

Endpoint Admission Defense (EAD)

MPLS

LDP, Static LSP

L3VPN: MCE/multirole host

L2VPN: Martini, Kompella, CCC, SVC

High availability

VRRP, VRRPv3

Bandwidth-based load balancing and backup

IP address-based load balancing and backup

NQA collaboration with routing, VRRP or interface backup

Management and maintenance

SNMPv1/v2c/v3, MIB, Syslog, RMON

Branch Intelligent Management System (BIMS), deployment from a USB drive

CLI, file system, and dual image

DHCP, FTP, HTTP, ICMP, UDP public, UDP private, TCP public, TCP private, and SNMP NQA tests

Console port login, Telnet (VTY) login, SSH login, FTP login

EAA

Virtualization

Integration of a highly available and high-performance open virtualization platform that supports third-party operating systems, such as Windows, CentOS, Ubuntu, and RedHat

Complete lifecycle management of virtual machines, including VM creation, modification, startup, suspend, recovery, hibernation, reboot, shutdown, and power-off

Monitoring of critical VM resources, such as vCPU, memory, disk I/O, and network I/O

Support of high-performance virtualization Ethernet adapter and SR-IOV

Support of fast app deployment, app deployment to VMs through a USB drive, and unified app deployment across the network

Complete troubleshooting and recovery mechanism

Scheduled backup and manual backup

Real-time monitoring of VM state

VM anomaly detection and auto reboot

Integration of Docker and Kubelet functions, allowing deployment of third-party applications on the device as containers through Docker or Kubernetes

SRv6

·         Support L2VPN over SRv6 in TE or BE mode

·         Support L3VPN over SRv6 in TE or BE mode

·         Support EVPN L2VPN over SRv6 in TE or BE mode

·         Support EVPN L3VPN over SRv6 in TE or BE mode

·         Support public network IP over SRv6 in TE or BE mode

·         Support SRv6 OAM

·         Support SRv6 TI-LFA FRR

·         Support SRv6 TE policy and SBFD collaboration

·         Support BGP-LS for SRv6

·         Support CBTS based on the five tuples for SRv6

Support color-, tunnel policy-, and DSCP-based traffic steering in an SRv6 TE policy scenario

iFIT

·         Support iFIT in an L3VPN over SRv6 scenario in TE or BE mode

·         Support iFIT in an EVPN L3VPN over SRv6 scenario in TE or BE mode

·         Support iFIT in a public network IP over SRv6 scenario in TE or BE mode

 

 


Appendix B Upgrading software

This section describes how to upgrade system software while the router is operating normally or when the router cannot correctly start up.

Software types

The following software types are available:

·          Boot ROM image—A .bin file that comprises a basic section and an extended section. The basic section is the minimum code that bootstraps the system. The extended section enables hardware initialization and provides system management menus. You can use these menus to load application software and the startup configuration file or manage files when the device cannot correctly start up.

·          Comware image—Includes the following image subcategories:

¡  Boot image—A .bin file that contains the Linux operating system kernel. It provides process management, memory management, file system management, and the emergency shell.

¡  System image—A .bin file that contains the minimum feature modules required for device operation and some basic features, including device management, interface management, configuration management, and routing. To have advanced features, you must purchase feature packages.

¡  Feature package—Includes a set of advanced software features. Users purchase feature packages as needed.

¡  Patch packages—Irregularly released packages for fixing bugs without rebooting the device. A patch package does not add new features or functions.

Comware software images that have been loaded are called "current software images." Comware images specified to load at the next startup are called "startup software images."

Boot ROM image, boot image, and system image are required for the system to work. These images might be released separately or as a whole in one .ipe package file. If an .ipe file is used, the system automatically decompresses the file, loads the .bin boot and system images and sets them as startup software images.

Upgrade methods

You can upgrade system software by using one of the following methods:

 

Upgrade method

Remarks

Upgrading from the CLI

You must reboot the router to complete the upgrade.

This method can interrupt ongoing network services.

Upgrading from the BootWare menu

Use this method when the router cannot correctly start up.

 

Preparing for the upgrade

Before you upgrade system software, complete the following tasks:

·          Set up the upgrade environment as shown in Table 7.

·          Configure routes to make sure that the router and the file server can reach each other.

·          Run a TFTP or FTP server on the file server.

·          Log in to the CLI of the router through the console port.

·          Copy the upgrade file to the file server and correctly set the working directory on the TFTP or FTP server.

·          Make sure the upgrade has minimal impact on the network services. During the upgrade, the router cannot provide any services.

 

IMPORTANT

IMPORTANT:

In the BootWare menu, if you choose to download files over Ethernet, the Ethernet port must be M-GE0 on an SR6602-I or SR6602-IE router.

 

Table 6 Storage media

Model

Storage medium

Path

Router Types

SR6602-I

eMMC

sda0:/

Centralized devices

SR6602-IE

eMMC

sda0:/

Centralized devices

 

Figure 1 Set up the upgrade environment

 

Upgrading from the CLI

You can use the TFTP or FTP commands on the router to access the TFTP or FTP server to back up or download files.

Saving the running configuration and verifying the storage space

1.          Save the running configuration.

<Sysname> save

The current configuration will be written to the device. Are you sure? [Y/N]:y

Please input the file name(*.cfg)[sda0:/startup.cfg]

(To leave the existing filename unchanged, press the enter key):

Validating file. Please wait...

Saved the current configuration to mainboard device successfully.

<Sysname>

2.         Identify the system software image and configuration file names and verify that the sda0 has sufficient space for the new system software image.

<Sysname> dir

Directory of sda0: (VFAT)

   0 -rw-           0 Sep 18 2020 15:35:36   1

   1 drw-           - Aug 06 2020 17:37:32   core

   2 -rw-          60 Aug 03 2020 17:53:42   database.dhcp

   3 -rw-     5815756 Aug 21 2020 16:19:12   diag.tar.gz

   4 -rw-     5814047 Aug 18 2020 17:36:20   diag_SR6602-I_20200818-173359.tar.g

z

   5 -rw-     5814117 Aug 18 2020 17:42:30   diag_SR6602-I_20200818-174021.tar.g

z

   6 drw-           - Jul 15 2020 15:14:12   diagfile

   7 -rw-        2429 Sep 21 2020 16:48:35   ifindex.dat

   8 drw-           - Sep 07 2020 10:50:04   license

   9 drw-           - Jul 15 2020 16:30:00   logfile

  10 drw-           - Jul 15 2020 16:37:20   pki

  11 drw-           - Jul 15 2020 15:14:12   seclog

  12 -rw-   208731136 Sep 07 2020 10:50:10   sr6602i-cmw910-boot-r9112p06.bin

  13 -rw-   175310848 Sep 07 2020 10:50:10   sr6602i-cmw910-system-r9112p06.bin

  14 -rw-    47334400 Sep 07 2020 10:50:10   sr6602i-cmw910-virtualization-r9112p06

.bin

  15 -rw-   431384576 Sep 04 2020 16:21:54   sr6602i.ipe

  16 -rw-       20373 Sep 21 2020 16:48:36   startup.cfg

  17 -rw-      447126 Sep 21 2020 16:48:36   startup.mdb

  18 drw-           - Jul 15 2020 15:15:52   third-party

  19 drw-           - Sep 07 2020 10:50:16   versionInfo

 

3139576 KB total (2266716 KB free)     <Sysname>

Downloading the image file to the router

Using TFTP

Download the system software image file to the sda0 on the router.

<Sysname> tftp 172.32.108.50 get sr6602i.ipe

Press CTRL+C to abort.

  % Total    % Received % Xferd  Average Speed   Time    Time     Time  Current

                                 Dload  Upload   Total   Spent    Left  Speed

100  127M  100  127M    0     0   719k      0  0:03:02  0:03:02 --:--:--  638k

Writing file...Done.

<Sysname>

Using FTP

1.          From FTP client view, download the system software image file to the CF card on the router.

<Sysname> ftp 172.32.108.50

Press CTRL+C to abort.

Connected to 172.32.108.50 (172.32.108.50).

220 3Com 3CDaemon FTP Server Version 2.0

User (172.32.108.50:(none)): 1

331 User name ok, need password

Password:

230 User logged in

Remote system type is UNIX.

Using binary mode to transfer files.

ftp> get sr6602i.ipe

sr6602i.ipe already exists. Overwrite it? [Y/N]:y

local: /mnt/slot1#sda0:/sr6602i.ipe remote: sr6602i.ipe

227 Entering passive mode (172,32,108,50,196,58)

125 Using existing data connection

....................................................................................................................................

226 Closing data connection; File transfer successful.

139764736 bytes received in 14.655 seconds (9.10 Mbytes/s)

ftp>

2.         Return to user view.

[ftp] quit

221 Service closing control connection

 

<Sysname>

Specifying the startup image file

1.          Specify the sr6602i.ipe file as the main image file at the next reboot.

<Sysname> boot-loader file sda0:/sr6602i.ipe all main

Verifying the file sda0:/sr6602i.ipe on slot 0....Done.

H3C SR6602I images in IPE:

  sr6602i-cmw910-boot-r9112p06.bin

  sr6602i-cmw910-system-r9112p06.bin

This command will set the main startup software images. Continue? [Y/N]:y

Add images to slot 1.

File sda0:/sr6602i-cmw910-boot-r9112p06.bin already exists on slot 0.

File sda0:/sr6602i-cmw910-system-r9112p06.bin already exists on slot 0.

Overwrite the existing files? [Y/N]:y

Decompressing file sda0:/sr6602i-cmw910-boot-r9112p06.bin to sda0:/sda0:/sr6602i-cmw910-boot-r9112p06.bin...Done.

Decompressing file sr6602i-cmw910-system-r9112p06.bin to sda0:/sr6602i-cmw910-system-r9112p06.bin...Done.

Verifying the file sda0:/sr6602i-cmw910-boot-r9112p06.bin on slot 0...Done.

Verifying the file sr6602i-cmw910-system-r9112p06.bin on slot 0....Done.

The images that have passed all examinations will be used as the main startup software images at the next reboot on slot 0.

Decompression completed.

Do you want to delete sda0:/sr6602i.ipe now? [Y/N]:y

<Sysname>

2.         Verify that the file has been loaded.

<Sysname> display boot-loader

Software images on slot 0:

Current software images:

  sda0:/sr6602i-cmw910-boot-r9112p06.bin

  sda0:/sr6602i-cmw910-system-r9112p06.bin

  sda0:/sr6602i-cmw910-virtualization-r9112p06.bin

Main startup software images:

  sda0:/sr6602i-cmw910-boot-r9112p06.bin

  sda0:/sr6602i-cmw910-system-r9112p06.bin

  sda0:/sr6602i-cmw910-virtualization-r9112p06.bin

Backup startup software images:

  None

<Sysname>

Rebooting and completing the upgrade

1.          Reboot the router.

<Sysname> reboot

Start to check configuration with next startup configuration file, please wait.........DONE!

This command will reboot the device. Continue? [Y/N]:y

Now rebooting, please wait...

<Sysname>

System is starting...

2.         After the reboot is complete, verify that the system software image is correct.

<Sysname> display version

H3C Comware Software, Version 9.0.001, Release 9112P06

Copyright (c) 2004-2021 New H3C Technologies Co., Ltd. All rights reserved.

H3C SR6602 uptime is 0 weeks, 0 days, 0 hours, 0 minutes

Last reboot reason : User reboot

Boot image: sda0:/sr6602i-cmw910-boot-r9112p06.bin

Boot image version: 9.0.001, Release 9112P06

  Compiled Sep 21 2020 14:00:00

System image: sda0:/sr6602i-cmw910-system-r9112p06.bin

System image version: 9.0.001, Release 9112P06

  Compiled Sep 21 2020 14:00:00

Feature image(s) list:

  sda0:/sr6602i-cmw910-virtualization-r9112p06.bin, version: 9.0.001

    Compiled Sep 21 2020 14:00:00

 

Slot 0: RT-SR6602-IE uptime is 0 week, 0 day, 0 hour, 0 minute

 Last reboot reason : User reboot

 CPU ID: 2

 128G bytes DDR4 SDRAM Memory

 32M bytes Flash Memory

 PCB              Version: B

 FPGA             Version: 2.12

 Basic      CPLD  Version: 1.0

 Extend     CPLD  Version: 1.0

 Basic   BootWare Version: 1.14

 Extend  BootWare Version: 1.14

 [FIXED PORTS] CON              (Hardware)Ver.B,   (Driver)1.0,   (CPLD)1.0

 [FIXED PORTS] MGE              (Hardware)Ver.B,   (Driver)1.0,   (CPLD)1.0

 [FIXED PORTS] 6XGE             (Hardware)Ver.B,   (Driver)1.0,   (CPLD)1.0

 [FIXED PORTS] 14XGSW           (Hardware)Ver.B,   (Driver)1.0,   (CPLD)1.0

 [FIXED PORTS] 12GSW            (Hardware)Ver.B,   (Driver)1.0,   (CPLD)1.0

 

Slot 1: RT-FIP-30 uptime is 0 week, 0 day, 0 hour, 0 minute

 Last reboot reason : User reboot

 PCB              Version: A

 FPGA             Version: 3.12

 CPLD             Version: 1.0

 [FIXED PORTS] 4XGE             (Hardware)Ver.A,   (Driver)1.0,   (CPLD)1.0

 [FIXED PORTS] 16XGE            (Hardware)Ver.A,   (Driver)1.0,   (CPLD)1.0

Upgrading from the BootWare menu

You can use the following methods to upgrade software from the BootWare menu:

·          Using TFTP/FTP to upgrade software through an Ethernet port

·          Using XMODEM to upgrade software through the console port

Accessing the BootWare menu

1.          Power on the router , and you can see the following information:

System is starting...

Booting Normal Extend BootWare

The Extend BootWare is self-decompressing....Done.

 

****************************************************************************

*                                                                           *

*                       H3C SR6602 BootWare, Version 1.14                   *

*                                                                           *

****************************************************************************

Copyright (c) 2004-2021 New H3C Technologies Co., Ltd.

 

Compiled Date       : Apr 22 2021

CPU ID              : 0x1

Memory Type         : DDR3 SDRAM

Memory Size         : 1024MB

Flash Size          : 2MB

Nand Flash size     : 256MB

CPLD Version        : 2.0

PCB Version         : 3.0

 

 

BootWare Validating...

Press Ctrl+B to access EXTENDED-BOOTWARE MENU...

2.         Press Ctrl + B to access the BootWare menu.

Password recovery capability is enabled.

Note: The current operating device is sda0

Enter < Storage Device Operation > to select device.

 

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                           |

|<2> Enter Serial SubMenu                                                  |

|<3> Enter Ethernet SubMenu                                                |

|<4> File Control                                                          |

|<5> Restore to Factory Default Configuration                              |

|<6> Skip Current System Configuration                                     |

|<7> BootWare Operation Menu                                               |

|<8> Skip authentication for console login                                 |

|<9> Storage Device Operation                                              |

|<0> Reboot                                                                |

============================================================================

Ctrl+Z: Access EXTENDED ASSISTANT MENU

Ctrl+F: Format File System

Enter your choice(0-9):

Table 7 BootWare menu options

Item

Description

<1> Boot System

Boot the system software image.

<2> Enter Serial SubMenu

Access the Serial submenu (see Table 10 ) for upgrading system software through the console port or changing the serial port settings.

<3> Enter Ethernet SubMenu

Access the Ethernet submenu (see Table 8) for upgrading system software through an Ethernet port or changing Ethernet settings.

<4> File Control

Access the File Control submenu (see Table 11) to retrieve and manage the files stored on the router.

<5> Restore to Factory Default Configuration

Delete the next-startup configuration files and load the factory-default configuration.

<6> Skip Current System Configuration

Start the router with the factory default configuration. This is a one-time operation and does not take effect at the next reboot. You use this option when you forget the console login password.

<7> BootWare Operation Menu

Access the BootWare Operation menu for backing up, restoring, or upgrading BootWare. When you upgrade the system software image, BootWare is automatically upgraded. H3C does not recommend upgrading BootWare separately. This document does not cover using the BootWare Operation menu.

<8> Skip authentication for console login

Clear all the authentication schemes on the console port.

<9> Storage Device Operation

Access the Storage Device Operation menu to manage storage devices. Using this option is beyond this chapter.

<0> Reboot

Restart the router.

 

Using TFTP/FTP to upgrade software through an Ethernet port

1.          Enter 3 in the BootWare menu to access the Ethernet submenu.

===============================<File CONTROL>===============================

|Note:the operating device is sda0                                        |

|<1> Download Image Program To SDRAM And Run                               |

|<2> Update Main Image File                                                |

|<3> Update Backup Image File                                              |

|<4> Download Files(*.*)                                                   |

|<5> Modify Ethernet Parameter                                     |

|<0> Exit To Main Menu                                                      |

============================================================================

Enter your choice(0-4):

Table 8 dEthernet submenu options

Item

Description

<1> Download Application Program To SDRAM And Run

Download a system software image to the SDRAM and run the image.

<2> Update Main Image File

Upgrade the main system software image.

<3> Update Backup Image File

Upgrade the backup system software image.

<4> Download Files(*.*)

Download a system software image to the Flash or CF card.

<5> Modify Ethernet Parameter

Modify network settings.

<0> Exit To Main Menu

Return to the BootWare menu.

 

2.         Enter 5 to configure the network settings.

=========================<ETHERNET PARAMETER SET>=========================

|Note:       '.' = Clear field.                                            |

|            '-' = Go to previous field.                                   |

|          Ctrl+D = Quit.                                                  |

==========================================================================

Protocol (FTP or TFTP) :ftp

Load File Name         :sr6602i.ipe

                       :

Target File Name       :sr6602i.ipe

                       :

Server IP Address      :192.168.1.1

Local IP Address       :192.168.1.100

Subnet Mask            :255.255.255.0

Gateway IP Address     :0.0.0.0

FTP User Name          :user001

FTP User Password      :********

Table 9 Network parameter fields and shortcut keys

Field

Description

'.' = Clear field

Press a dot (.) and then Enter to clear the setting for a field.

'-' = Go to previous field

Press a hyphen (-) and then Enter to return to the previous field.

Ctrl+D = Quit

Press Ctrl + D to exit the Ethernet Parameter Set menu.

Protocol (FTP or TFTP)

Set the file transfer protocol to FTP or TFTP.

Load File Name

Set the name of the file to be downloaded.

Target File Name

Set a file name for saving the file on the router. By default, the target file name is the same as the source file name.

Server IP Address

Set the IP address of the FTP or TFTP server. If a mask must be set, use a colon (:) to separate the mask length from the IP address. For example, 192.168.80.10:24.

Local IP Address

Set the IP address of the router.

Subnet Mask

Subnet Mask of the local IP address.

Gateway IP Address

Set a gateway IP address if the router is on a different network than the server.

FTP User Name

Set the username for accessing the FTP server. This username must be the same as configured on the FTP server. This field is not available for TFTP.

FTP User Password

Set the password for accessing the FTP server. This password must be the same as configured on the FTP server. This field is not available for TFTP.

 

3.         Select an option in the Ethernet submenu to upgrade a system software image. For example, enter 2 to upgrade the main system software image.

Loading.....................................................................

............................................................................

............................................................................

.........................................Done.

37691392 bytes downloaded!

The file already exists,will you overwrite it? [Y/N]Y

Image file sr6602i-cmw910-boot-r9112p06.bin is self-decompressing...

Saving file sda0:/sr6602i-cmw910-boot-r9112p06.bin.bin .................

Done.

Image file sr6602i-cmw910-system-r9112p06.bin is self-decompressing...

Saving file sda0:/sr6602i-cmw910-system-r9112p06.bin.bin .................

............................................................................

...........................Done.

 

==========================<Enter Ethernet SubMenu>==========================

|Note:the operating device is sda0                                         |

|<1> Download Image Program To SDRAM And Run                               |

|<2> Update Main Image File                                                |

|<3> Update Backup Image File                                              |

|<4> Download Files(*.*)                                                   |

|<5> Modify Ethernet Parameter                                             |

|<0> Exit To Main Menu                                                     |

|<Ensure The Parameter Be Modified Before Downloading!>                    |

============================================================================

Enter your choice(0-5):

4.         Enter 0 to return to the BootWare menu

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                           |

|<2> Enter Serial SubMenu                                                  |

|<3> Enter Ethernet SubMenu                                                |

|<4> File Control                                                          |

|<5> Modify BootWare Password                                              |

|<6> Skip Current System Configuration                                     |

|<7> BootWare Operation Menu                                               |

|<8> Skip authentication for console login                                 |

|<9> Storage Device Operation                                              |

|<0> Reboot                                                                |

============================================================================

Enter your choice(0-9):

5.         1 to boot the system.

Loading the main image files...

Loading file sda0:/sr6602i-cmw910-system-e0901p01.bin..........................

Done.

Loading file sda0:/sr6602i-cmw910-boot-e0901p01.bin..............Done.

 

Image file sda0:/sr6602i-cmw910-boot-e0901p01.bin is self-decompressing.........

.....Done.

System image is starting...

Line aux0 is available.

 

 

Press ENTER to get started.

Using XMODEM to upgrade software through the console port

1.          Enter 2 in the BootWare menu to access the Serial submenu.

===========================<Enter Serial SubMenu>===========================

|Note:the operating device is sda0                                         |

|<1> Download Image Program To SDRAM And Run                               |

|<2> Update Main Image File                                                |

|<3> Update Backup Image File                                              |

|<4> Download Files(*.*)                                                   |

|<5> Modify Serial Interface Parameter                                     |

|<0> Exit To Main Menu                                                     |

============================================================================

Enter your choice(0-4):

Table 10 Serial submenu options

Item

Description

<1> Download Application Program To SDRAM And Run

Download an application to SDRAM through the serial port and run the program.

<2> Update Main Image File

Upgrade the main system software image.

<3> Update Backup Image File

Upgrade the backup system software image.

<4>Download Files(*.*)

Download a system software image to the Flash or CF card.

<5> Modify Serial Interface Parameter

Modify serial port parameters

<0> Exit To Main Menu

Return to the BootWare menu.

 

2.         Enter 5 Select an appropriate baud rate for the console port. For example, enter 5 to select 115200 bps.

===============================<BAUDRATE SET>===============================

|Note:'*'indicates the current baudrate                                    |

|     Change The HyperTerminal's Baudrate Accordingly                      |

|---------------------------<Baudrate Available>---------------------------|

|<1> 9600(Default)*                                                        |

|<2> 19200                                                                 |

|<3> 38400                                                                 |

|<4> 57600                                                                 |

|<5> 115200                                                                |

|<0> Exit                                                                  |

============================================================================

Enter your choice(0-5):

The following messages appear:

Baudrate has been changed to 115200 bps.

Please change the terminal's baudrate to 115200 bps, press ENTER when ready.

 

 

NOTE:

Typically the size of a .bin file is over 10 MB. Even at 115200 bps, the download takes about 30 minutes.

 

3.         Select Call > Disconnect in the HyperTerminal window to disconnect the terminal from the router.

Figure 2 Disconnect the terminal connection

 

 

NOTE:

If the baud rate of the console port is 9600 bps, jump to step 9.

 

4.         Select File > Properties, and in the Properties dialog box, click Configure.

Figure 3 Properties dialog box

 

5.         Select 115200 from the Bits per second list and click OK.

Figure 4 Modify the baud rate

 

6.         Select Call > Call to reestablish the connection.

Figure 5 Reestablish the connection

 

7.         Press Enter.

The following menu appears:

The current baudrate is 115200 bps

 

===============================<BAUDRATE SET>===============================

|Note:'*'indicates the current baudrate                                    |

|     Change The HyperTerminal's Baudrate Accordingly                      |

|---------------------------<Baudrate Available>---------------------------|

|<1> 9600(Default)                                                         |

|<2> 19200                                                                 |

|<3> 38400                                                                 |

|<4> 57600                                                                 |

|<5> 115200*                                                               |

|<0> Exit                                                                  |

============================================================================

Enter your choice(0-5):

8.         Enter 0 to return to the Serial submenu.

===========================<Enter Serial SubMenu>===========================

|Note:the operating device is sda0                                         |

|<1> Download Image Program To SDRAM And Run                               |

|<2> Update Main Image File                                                |

|<3> Update Backup Image File                                              |                                                        |<4> Download Files(*.*)                                                   |

|<5> Modify Serial Interface Parameter                                     |

|<0> Exit To Main Menu                                                     |

============================================================================

Enter your choice(0-4):

9.         Select an option from options 2 to 3 to upgrade a system software image. For example, enter 2 to upgrade the main system software image.

Please Start To Transfer File, Press <Ctrl+C> To Exit.

Waiting ...CCCCC

10.       Select Transfer > Send File in the HyperTerminal window.

Figure 6 Transfer menu

 

11.        In the dialog box that appears, click Browse to select the source file, and select Xmodem from the Protocol list.

Figure 7 File transmission dialog box

 

12.       Click Send. The following dialog box appears:

Figure 8 File transfer progress

 

13.       When the Serial submenu appears after the file transfer is complete, enter 0 at the prompt to return to the BootWare menu.

Download successfully!

37691392 bytes downloaded!

Input the File Name:main.bin

Updating File sda0:/main.bin..............................................

.....................................................Done!

 

===========================<Enter Serial SubMenu>===========================

|Note:the operating device is sda0                                         |

|<1> Download Image Program To SDRAM And Run                               |

|<2> Update Main Image File                                                |

|<3> Update Backup Image File                                              |                                                        |<4> Download Files(*.*)                                                   |

|<5> Modify Serial Interface Parameter                                     |

|<0> Exit To Main Menu                                                     |

============================================================================

Enter your choice(0-4):

14.       Enter 1 in the BootWare menu to boot the system.

15.       If you are using a download rate other than 9600 bps, change the baud rate of the terminal to 9600 bps. If the baud rate has been set to 9600 bps, skip this step.

Managing files from the BootWare menu

To change the type of a system software image, retrieve files, or delete files, enter 4 in the BootWare menu.

The File Control submenu appears:

==============================<File CONTROL>==============================

|Note:the operating device is sda0                                       |

|<1> Display All File(s)                                                 |

|<2> Set Image File type                                                 |

|<3> Set Bin File type                                                   |

|<4> Set Configuration File type                                         |

|<5> Delete File                                                         |

|<6> Copy File                                                           |

|<0> Exit To Main Menu                                                   |

==========================================================================

Enter your choice(0-6):

Table 11 File Control submenu options

Item

Description

<1> Display All File

Display all files.

<2> Set Image File type

Change the type of a system software image (.ipe).

<3> Set Bin File type

Change the type of a system software image (.bin).

<4> Set Configuration File type

Change the type of a configuration file.

<5> Delete File

Delete files.

<6> Copy File

Copy File

<0> Exit To Main Menu

Return to the BootWare menu.

 

Displaying all files

To display all files, enter 1 in the File Control submenu:

Display all file(s) in sda0:

 'M' = MAIN      'B' = BACKUP      'N/A' = NOT ASSIGNED

============================================================================

|NO. Size(B)   Time                 Type   Name                            |

|1   37691392  May/16/2021 07:09:16 N/A    sda0:/sr6602i.ipe               |

|2   25992     May/16/2021 12:18:00 N/A    sda0:/startup.mdb               |

|3   1632      May/16/2021 12:18:00 M      sda0:/startup.cfg               |

|4   84        May/16/2021 12:17:59 N/A    sda0:/ifindex.dat               |

|5   11029     May/16/2021 13:31:16 N/A    sda0:/logfile/logfile1.log      |

|6   17        May/16/2021 07:47:24 N/A    sda0:/.pathfile                 |

|7   1006592   May/16/2021 07:44:16 M      sda0:sr6602i-cmw910-data-r9112p06.bin|

|8   815       May/16/2021 12:03:14 N/A    sda0:/license/DeviceID.did           |

|9   1180672   May/16/2021 07:44:15 M      sda0:/sr6602i-cmw910-voice-r9112p06. bin|

|10  10240     May/16/2021 07:44:15 M      sda0:/sr6602i-cmw910-security-r9112p06.bin|

|11  24067072  May/16/2021 07:44:10 M      sda0:/sr6602i-cmw910-system-r9112p06.bin  |

|12  11418624  May/16/2021 07:44:05 M      sda0:/sr6602i-cmw910-boot-r9112p06.bin   |

============================================================================

Changing the type of a system software image

System software image file attributes include main (M), and backup (B). You can store only one main image, and one backup image on the router. A system software image can have any combination of the M, and B attributes. If the file attribute you are assigning has been assigned to an image, the assignment removes the attribute from that image. The image is marked as N/A if it has only that attribute.

To change the type of a system software image:

1.          Enter 2 in the File Control submenu.

'M' = MAIN      'B' = BACKUP      'N/A' = NOT ASSIGNED

============================================================================

|NO. Size(B)   Time                 Type   Name                            |

|1   37691392  May/16/2021 07:09:16 N/A    sda0:/sr6602i.ipe               |

|0   Exit                                                                  |

============================================================================

Enter file No:1

2.         Enter the number of the file you are working with, and press Enter.

Modify the file attribute:

==========================================================================

|<1> +Main                                                               |

|<2> +Backup                                                             |

|<0> Exit                                                                |

==========================================================================

Enter your choice(0-2):

3.         Enter a number in the range of 1 to 4 to add or delete a file attribute for the file.

Set the file attribute success!

Deleting files

When storage space is insufficient, you can delete obsolete files to free up storage space.

To delete files:

1.          Enter 5 in the File Control submenu.

Deleting the file in sda0:

 'M' = MAIN      'B' = BACKUP      'N/A' = NOT ASSIGNED

============================================================================

|NO. Size(B)   Time                 Type   Name                            |

|NO. Size(B)   Time                 Type   Name                            |

|1   37691392  May/16/2021 07:09:16 N/A    sda0:/sr6602i.ipe               |

|2   25992     May/16/2021 12:18:00 N/A    sda0:/startup.mdb               |

|3   1632      May/16/2021 12:18:00 M      sda0:/startup.cfg               |

|4   84        May/16/2021 12:17:59 N/A    sda0:/ifindex.dat               |

|5   11029     May/16/2021 13:31:16 N/A    sda0:/logfile/logfile1.log      |

|6   17        May/16/2021 07:47:24 N/A    sda0:/.pathfile                 |

|7   1006592   May/16/2021 07:44:16 M      sda0:sr6602i-cmw910-data-r9112p06.bin|

|8   815       May/16/2021 12:03:14 N/A    sda0:/license/DeviceID.did      |

|9   1180672   May/16/2021 07:44:15 M      sda0:/sr6602i-cmw910-voice-r9112p06. bin|

|10  10240     May/16/2021 07:44:15 M      sda0:/sr6602i-cmw910-security-r9112p06.bin|

|11  24067072  May/16/2021 07:44:10 M      sda0:/sr6602i-cmw910-system-r9112p06.bin|

|12  11418624  May/16/2021 07:44:05 M      sda0:/sr6602i-cmw910-boot-r9112p06.bin|

0   Exit

Enter file No.:

2.         Enter the number of the file to delete.

3.         When the following prompt appears, enter Y.

The file you selected is sda0:/sr6602i-cmw910-security-r9112p06.bin,Delete it?

[Y/N]Y

Deleting...Done.

Handling software upgrade failures

If a software upgrade fails, the system runs the old software version. To handle a software failure:

1.          Check the physical ports for a loose or incorrect connection.

2.         If you are using the console port for file transfer, check the HyperTerminal settings (including the baud rate and data bits) for any wrong setting.

3.         Check the file transfer settings:

¡  If XMODEM is used, you must set the same baud rate for the terminal as for the console port.

¡  If TFTP is used, you must enter the same server IP addresses, file name, and working directory as set on the TFTP server.

¡  If FTP is used, you must enter the same FTP server IP address, source file name, working directory, and FTP username and password as set on the FTP server.

4.         Check the FTP or TFTP server for any incorrect setting.

5.         Check that the storage device has sufficient space for the upgrade file.

6.         If the message “Something is wrong with the file” appears, check the file for file corruption.

Appendix C Handling console login password loss

Disabling password recovery capability

Password recovery capability controls console user access to the device configuration and SDRAM from BootWare menus.

If password recovery capability is enabled, a console user can access the device configuration without authentication to configure new passwords.

If password recovery capability is disabled, console users must restore the factory-default configuration before they can configure new passwords. Restoring the factory-default configuration deletes the next-startup configuration files.

To enhance system security, disable password recovery capability.

Table 12 summarizes options whose availability varies with the password recovery capability setting.

Table 12 BootWare options and password recovery capability compatibility matrix

BootWare menu option

Password recovery enabled

Password recovery disabled

Tasks that can be performed

Download Image Program To SDRAM And Run

Yes

No

Load and run Comware software images in SDRAM.

Skip Authentication for Console Login

Yes

No

Enable console login without authentication.

Skip Current System Configuration

Yes

No

Load the factory-default configuration without deleting the next-startup configuration files.

Restore to Factory Default Configuration

No

Yes

Delete the next-startup configuration files and load the factory-default configuration.

 

To disable password recovery capability:

 

Step

Command

Remarks

1.        Enter system view.

system-view

N/A

2.       Disable password recovery capability.

undo password-recovery enable

By default, password recovery capability is enabled.

 

When password recovery capability is disabled, you cannot downgrade the device software to a version that does not support the capability through the BootWare menus. You can do so at the CLI, but the BootWare menu password configured becomes effective again.

Handling console login password loss

 

CAUTION

CAUTION:

Handling console login password loss causes service outage.

 

The method for handling console login password loss depends on the password recovery capability setting (see Figure 9).

Figure 9 Handling console login password loss

 

Examining the password recovery capability setting

1.          Reboot the router.

System is starting...

Press Ctrl+D to access BASIC-BOOTWARE MENU...

Press Ctrl+T to start heavy memory test

Booting Normal Extended BootWare........

The Extended BootWare is self-decompressing....Done.

 

****************************************************************************

*                                                                          *

*                       H3C SR6602 BootWare, Version 1.14                  *

*                                                                          *

****************************************************************************

Copyright (c) 2004-2021 New H3C Technologies Co., Ltd.

 

Compiled Date       : May 13 2021

CPU ID              : 0x2

Memory Type         : DDR3 SDRAM

Memory Size         : 2048MB

BootWare Size       : 1024KB

Flash Size          : 8MB

cfa0 Size           : 247MB

CPLD Version        : 2.0

PCB Version         : 2.0

 

 

BootWare Validating...

Press Ctrl+B to access EXTENDED-BOOTWARE MENU...

2.         Press Ctrl + B within three seconds after the "Press Ctrl+B to access EXTENDED-BOOTWARE MENU..." prompt message appears.

3.         Read the password recovery capability setting information displayed before the EXTEND-BOOTWARE menu.

Password recovery capability is enabled.

Note: The current operating device is sda0

Enter < Storage Device Operation > to select device.

 

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                            |

|<2> Enter Serial SubMenu                                                   |

|<3> Enter Ethernet SubMenu                                                 |

|<4> File Control                                                           |

|<5> Restore to Factory Default Configuration                               |

|<6> Skip Current System Configuration                                      |

|<7> BootWare Operation Menu                                                |

|<8> Skip Authentication for Console Login                                  |

|<9> Storage Device Operation                                               |

|<0> Reboot                                                                 |

============================================================================

Ctrl+Z: Access EXTEND ASSISTANT MENU

Ctrl+F: Format File System

Enter your choice(0-9):

Using the Skip Current System Configuration option

1.          Reboot the router to access the EXTEND-BOOTWARE menu, and then enter 6.

The current mode is password recovery.

Note: The current operating device is sda0

Enter < Storage Device Operation > to select device.

 

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                            |

|<2> Enter Serial SubMenu                                                   |

|<3> Enter Ethernet SubMenu                                                 |

|<4> File Control                                                           |

|<5> Restore to Factory Default Configuration                               |

|<6> Skip Current System Configuration                                      |

|<7> BootWare Operation Menu                                                |

|<8> Skip Authentication for Console Login                                  |

|<9> Storage Device Operation                                               |

|<0> Reboot                                                                 |

============================================================================

Ctrl+Z: Access EXTEND ASSISTANT MENU

Ctrl+F: Format File System

Enter your choice(0-9): 6

After the configuration skipping flag is set successfully, the following message appears:

Flag Set Success.

2.         When the EXTEND-BOOTWARE menu appears again, enter 1 to reboot the router.

The router starts up with the factory-default configuration without deleting the next-startup configuration files.

3.         To use the configuration in a next-startup configuration file, load the file in system view.

<H3C> system-view

[H3C] configuration replace file sda0:/startup.cfg

Current configuration will be lost, save current configuration? [Y/N]:n

Info: Now replacing the current configuration. Please wait...

Info: Succeeded in replacing current configuration with the file startup.cfg.

4.         Configure a new console login authentication mode and a new console login password.

In the following example, the console login authentication mode is password and the authentication password is 123456. For security purposes, the password is always saved in ciphertext, whether you specify the simple or cipher keyword for the set authentication password command.

<H3C> system-view

[H3C] line console 0

[H3C-line-console0] authentication-mode password

[H3C-line-console0] set authentication password simple 123456

Use the line console 0 command on an SR6602i router. The console port and the Console port are the same physical port.

5.         To make the settings take effect after a reboot, save the running configuration to the next-startup configuration file.

[H3C-line-console0] save

Using the Skip Authentication for Console Login option

1.          Reboot the router to access the EXTEND-BOOTWARE menu, and then enter 8.

The current mode is password recovery.

Note: The current operating device is sda0

Enter < Storage Device Operation > to select device.

 

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                            |

|<2> Enter Serial SubMenu                                                   |

|<3> Enter Ethernet SubMenu                                                 |

|<4> File Control                                                           |

|<5> Restore to Factory Default Configuration                               |

|<6> Skip Current System Configuration                                      |

|<7> BootWare Operation Menu                                                |

|<8> Skip Authentication for Console Login                                  |

|<9> Storage Device Operation                                               |

|<0> Reboot                                                                 |

============================================================================

Ctrl+Z: Access EXTEND ASSISTANT MENU

Ctrl+F: Format File System

Enter your choice(0-9): 8

The router deletes the console login authentication configuration commands from the main next-startup configuration file. After the operation is completed, the following message appears:

Clear Image Password Success!

2.         When the EXTEND-BOOTWARE menu appears again, enter 1 to reboot the router.

The router starts up with the main next-startup configuration file.

3.         Configure a console login authentication mode and a new console login password. See

"Configure a new console login authentication mode and a new console login password.."

4.         To make the setting take effect after a reboot, save the running configuration to the next-startup configuration file.

[H3C-line-console0] save

Using the Restore to Factory Default Configuration option

 

CAUTION

CAUTION:

Using the Restore to Factory Default Configuration option deletes both the main and backup next-configuration files.

 

1.          Reboot the router to access the EXTEND-BOOTWARE menu, and enter 5.

The current mode is no password recovery.

Note: The current operating device is sda0

Enter < Storage Device Operation > to select device.

 

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                            |

|<2> Enter Serial SubMenu                                                   |

|<3> Enter Ethernet SubMenu                                                 |

|<4> File Control                                                           |

|<5> Restore to Factory Default Configuration                               |

|<6> Skip Current System Configuration                                      |

|<7> BootWare Operation Menu                                                |

|<8> Skip Authentication for Console Login                                  |

|<9> Storage Device Operation                                               |

|<0> Reboot                                                                 |

============================================================================

Ctrl+Z: Access EXTEND ASSISTANT MENU

Ctrl+F: Format File System

Enter your choice(0-9): 5

2.         At the prompt for confirmation, enter Y.

The router deletes its main and backup next-startup configuration files and restores the factory-default configuration.

The current mode is no password recovery. The configuration files will be

deleted, and the system will start up with factory defaults, Are you sure to

 continue?[Y/N]Y

Setting...Done.

3.         When the EXTEND-BOOTWARE menu appears again, enter 1 to reboot the router.

The router starts up with the factory-default configuration.

4.         Configure a new console login authentication mode and a new console login password. See

"Configure a new console login authentication mode and a new console login password.."

5.         To make the settings take effect after a reboot, save the running configuration to the next-startup configuration file.

[H3C] save

 

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网